    IEC 60598-1: 2020 edition standard update instructions

    Author:中認(rèn)聯(lián)科 time:2020-09-21 Ctr:4474

    IEC 60598-1:2020 luminaires. Part 1 of general requirements and tests was officially released on August 17, 2020. IEC 60598-1:2020 is the ninth edition released this time and will replace IEC 60598-1:2014+A1 : The 2017 version.

    image.png

    Compared with the previous version, the new version includes the following major technical changes:

    1. Add PELV and related requirements. Due to transient protection circuits and EMC reasons, the market has a strong demand for PELV circuits. Considering IEC TR 63139 (under development), where SELV appears in the standard, the addition of PELV related modifications involves Chapter 3, Chapter 4, Chapter 7, Chapter 8, Chapter 10, Appendix X, etc.;

    2. Modified Table 10.3 and Article 3.3.19 for high protection currents. According to the regulations stated in the manual of 3.3.19, the power supply current limit of 20A or more shall be added on the basis of the original applicable objects, that is, the applicable objects of this clause are Permanently connected lamps with a power supply current of more than 20A and a protective conductor current of more than 10 mA, and the corresponding limit in Table 10.3 is changed from 10 mA to 10 mA or in accordance with the manufacturer’s instructions;

    3. Article 3.3.26 adds the marking requirements for wall-mounted lamps within the reach of the arm, and requires additional instructions for fixing the cable to the wall;

    4. Article 3.2.27 adds requirements for constant light output function and programmable current output;

    5. Article 4.30 Non-user replaces the electric shock protection cover used for light source lamps;

    6. Article 4.24.2 Blu-ray hazards delete category 0 hazards;

    7. Article 5.2.16 adds the component standard IEC 61984 that the connector should comply with, as well as additional requirements such as polarity interchange, mechanical locking, protection against electric shock, short circuit protection, and cable clamping;

    8. Article 3.3.25 adds the requirements of cable UV protection;

    9. Article 4.34 requires lamps not to emit harmful electromagnetic fields and should comply with EMF IEC 62493;

    10. Updated the functional grounding and protective grounding and their requirements in the 1.2.73 standard, including adding definitions, adding the qualifiers of "function" or "protection" to "grounding" in the clauses; in Appendix G, adding The description of the disconnection of the functional ground (if separate) when measuring the protective conductor current is added, and the functional ground terminal or contact that can be touched should be regarded as an accessible part and tested when measuring the contact current;

    11. Article 4.35 puts forward the test requirements to prevent the fan blades driven by the motor for cooling in the lamps from being touched, and gives the exemption test conditions, such as low hardness, low speed and low power;

    12. Article 3.2.2 Modify the marking requirements of rated voltage, delete the situation that does not need to be marked with rated voltage, that is, all lamps must be marked with rated voltage in volts;

    13. In the provisions of Article 5.2.10, the provisions that meet the requirements of 5.2.10.4 can be used as an exception to the use of flexible cord holders. The additional 5.2.10.4 provides for exceptional conditions, including overcurrent protection devices. The highest short-circuit current reached does not exceed 2A, and the highest voltage of various Class III lamps, and the corresponding qualification test requirements;

    14. The measurement network in Appendix G for the measurement of contact current and protective conductor current is revised;

    15. Modified the contact voltage limit value of irregular DC voltage in 8.2.3c);

    16. Article 1.2.96 Luminaires (PoE) that rely on Ethernet power supply that meets IEC 62368-3 power supply are connected, involving definitions, structures, thermal tests and an appendix introducing PoE luminaires;

    17. Article 9 IP adds high pressure and high temperature water blowout protection IPX9 (80℃) and high pressure and low temperature water blowout protection IPX9 (15℃) and its test requirements;

    18. Amended Appendix D to introduce alternative thermal tests for lamps whose ta mark is higher than 25℃;

    19. In Article 0.2, 4.14.1 was added, and relevant requirements for rail-mounted luminaires were added, including definitions, and rail-mounted luminaires were added to 4.14.1 test objects, and a requirement was added in Chapter 4, that is, rail-mounted luminaires It shall be tested in accordance with IEC 60570 Annex A;

    20. The test method of 10.2.2 to increase the electrical strength of DC lamps is modified;

    21. Amended Appendix D and added the temperature limit to Table 12.1 and Table 12.3. For lamps marked with F, the covering layer is changed to directly contact the lamp instead of covering the outside of the box before;

    22. The minimum torque of the metal gland test in Table 4.2 is reduced from 6.25 Nm to 4 Nm;

    23. Amend the requirements for protective impedance devices (4.10.4) in Section 4.10.4 and Appendix U, and modify the quantity requirements of Y1 and Y2 to be expressed in tables, and according to the power supply voltage, impulse withstand category, and insulation of the jumper And the number of capacitors required by the capacitor type (Y1, Y2 or Y4). The relevant amendments involve Chapter 4 and Appendix U;

    24. Amend the second paragraph of 5.2.14 to modify the category III plugs used in lamps and lanterns, in the original requirement that category III plugs cannot be connected to the grid power socket, "cannot be connected" is changed to "cannot be electrically connected", and The test method is added, and the relevant modification involves Chapter 5 and Chapter 4.


    Related Articles
    • Say Goodbye to Compliance Risks: Quick Guide to CCC Certification for Tablet PC Batteries

    • Avoid Pitfalls: How to Apply for PSE Certification for Bluetooth Speaker Batteries Exported to Japan

    • New Compliance Rules for Toys in South Korea: Application Guide for KC Certification of Remote Control Cars

    • Avoid Customs Detention in the EU! Core Requirements for CE Certification of Wireless Speakers

    Follow Us
    主站蜘蛛池模板: 国产无码8页| 蜜桃视频一区二区三区| 亚洲另类图| 欧美 在线 成 人怡红院| 视频二区一区国产精品天天| 久久福利影院| 欧美视频在线第一页| 一本久道久久综合狠狠躁av| 理论片午午伦夜理片久久| 自慰无码一区二区三区| 国产91精品调教在线播放| 99精品免费视频| 中文字幕精品久久久久人妻红杏1| 久久香蕉国产线看观看亚洲卡| 99热这里只有精品久久免费| 7777久久亚洲中文字幕| 精品国产乱码久久久久乱码| 日韩无码网站| 久9视频这里只有精品8| 视频一区二区无码制服师生| 热思思99re久久精品国产首页| 国产精品成人AV片| 日本欧美一区二区免费视频 | 欧产日产国产精品精品| 亚洲无码?制服丝袜| 亚洲乱亚洲乱妇无码| 侵犯强奷高清无码| 丰满少妇又爽又紧又丰满在线观看| 久久亚洲国产成人亚| 亚洲人成网站色7799在线观看| 丰满少妇av无码专区| 午夜精品久久久久久久久久老司机| 手机AV在线网站| 日韩内射美女片在线观看网站| 女人被男人爽到呻吟的视频| 亚洲精品一区二区三区大桥未久| 性史性农村dvd毛片| 亚洲爆乳大丰满无码专区| 亚洲美女av一区| 国内av网站| 国产一级毛片特级视频|